Hoshizaki“A Superior Degreeof Reliability”www.hoshizaki.comModelsDCM-750BAHDCM-750BAH-OSDCM-750BWHDCM-750BWH-OSCubelet Icemaker / DispenserHoshizaki

Strona 2 - IMPORTANT

02. DCM-750BWH(-OS)Storage BinInlet Water ValveReservoirControl BoxWater-Cooled CondenserSpout CoverEvaporator AssemblyCompressorDispensing Motor Agi

Strona 3 - CONTENTS

B. Ice Making Unit1. DCM-750BAH(-OS)Cubelet CutterAllen Head Cap ScrewGear MotorO-RingMechanical SealExtruding Headand Upper BearingHex Head Bolt wi

Strona 4

C. Sequence of OperationThe steps in the sequence are as outlined below. When power is supplied, the power switch is in the "ON" position,

Strona 5 - A. Icemaker

3Legend:BC - bin controlComp - compressorDC - drain cycleDT - drain timerDV - drain valveFMS - self-contained fan motorFT - ll timer (low water safe

Strona 6 - 2. DCM-750BAH-OS

4D. Control Board• A Hoshizaki exclusive solid-state control board is employed in DCM-750BAH, DCM-750BAH-OS, DCM-750BWH, and DCM-750BWH-OS Cubelet Ic

Strona 7 - 3. DCM-750BWH

5Microprocessor (board revision level indicated by last  digits on label)"POWER" LED(lights when power is supplied to the board)"FLUS

Strona 8 - 4. DCM-750BWH-OS

6Dispensing Components See "III.B. Wiring Diagrams" for details.Bin Control, Control Switch,Low Water SafetyMicroprocessor (board revision

Strona 9 - A. Construction

72. FeaturesThe control board provides the following safeguards:• Provides component protection during low water supply.• Purges remaining ice in the

Strona 10

83. Controls and Adjustments a) Portion ControlWhen the dispense mode switch is placed in the "PORTION" position, a variable resistor (loca

Strona 11 - B. Ice Making Unit

93. 60 seconds after the "GM" LED comes on, the "COMP" LED comes on, and the compressor and fan motor start. If the "COMP&qu

Strona 12 - C. Sequence of Operation

IMPORTANTOnly qualied service technicians should attempt to install, service, or maintain this icemaker. No service or maintenance should be underta

Strona 13 - Shutdown & Restart

0E. Float SwitchDepending on local water conditions, scale may build up on the oat switch. Scale on the switch can cause the oats to stick. In this

Strona 14 - D. Control Board

III. Technical InformationA. Water Circuit and Refrigeration Circuit1. DCM-750BAH(-OS)Inlet Water ValveDispensing Water ValveDrain ValveFloat Switch

Strona 15 - Control Board

2. DCM-750BWH(-OS) Inlet Water ValveDispensing Water ValveDrain ValveFloat SwitchWater LevelTo DrainEvaporatorSpoutExpansion ValveGear MotorOverowR

Strona 16

3BK BLACKBR BROWNBU BLUEDBU DARK BLUEGY GRAYLBU LIGHT BLUEO ORANGEP PINKR REDV VIOLETW WHITEY YELLOWW/BK WHITE/BLACKW/BR WHITE/BROWNW/BU WHITE/BLUEW/

Strona 17

42. DCM-750BAH-OS, DCM-750BWH-OS BK BLACKBR BROWNBU BLUEDBU DARK BLUEGY GRAYLBU LIGHT BLUEO ORANGEP PINKR REDV VIOLETW WHITEY YELLOWW/BK WHITE/BLACKW

Strona 18

5C. Sequence of Electrical Circuit – Ice Making1. Fill Cycle With the power switch in the "ON" position and the control switch in the "

Strona 19

62. Ice Purge Cycle Upper oat switch closes, water control relay energizes, inlet water valve closes, gear motor starts, gear motor protect relay en

Strona 20 - E. Float Switch

73. Freeze Cycle Compressor and fan motor start 60 seconds after gear motor starts.BK BLACK O ORANGE W/BK WHITE/BLACKBR BROWN P PINK W/BR WHITE/BROWN

Strona 21 - III. Technical Information

84. 12 Hour Drain Cycle / Drain Switch hour timer initiates cycle or the control switch is moved to the "DRAIN" position. 90 seconds afte

Strona 22 - 2. DCM-750BWH(-OS)

95. ShutdownThe bin control switch is activated and a 50 second shutdown sequence begins. After the bin control has been open for 90 seconds, the co

Strona 23 - B. Wiring Diagrams

3IMPORTANTThis manual should be read carefully before the icemaker is serviced ormaintenance operations are performed. Only qualied service technicia

Strona 24 - WIRE COLOR CODE

306. Low Water Safety Upper oat switch fails to close within 90 seconds after the lower oat switch opens, the 50 second shutdown sequence begins. T

Strona 25

37. High Pressure Switch When the high pressure switch opens, the compressor stops immediately, 60 seconds later the gear motor stops. To restart, al

Strona 26

3D. Sequence of Electrical Circuit – Dispensing 1. Continuous DispenseAgitating motor energizes for .6 seconds for every  seconds of accumulative d

Strona 27

332. Portion DispenseAgitating motor energizes for .6 seconds for every  seconds of accumulative dispense time. A variable resistor which controls t

Strona 28 - Manual Drain Cycle

34E. Performance Data1. DCM-750BAH(-OS)Note:. The data without *marks should be used for reference only.. We reserve the right to make changes in sp

Strona 29

352. DCM-750BWH(-OS)Note:. The data without *marks should be used for reference only.. We reserve the right to make changes in specications and des

Strona 30

36IV. Service DiagnosisA. Diagnostic ProcedureThis diagnostic procedure is a sequence check that allows you to diagnose the electrical system and comp

Strona 31

376) Rell /Low Water Safety – As ice is produced, the water level in the reservoir drops. As the water level drops, the upper and lower oat switches

Strona 32

38C. Diagnostic Charts1. No Ice ProductionProblem Possible Cause Remedy[]The icemaker will not start. (Fill Cycle)a) Power Supply . Off, blown fuse,

Strona 33

39Problem Possible Cause Remedy[]The icemaker will not start. (Fill Cycle) (continued)m)High Pressure Switch . Bad contacts. . Check for continuity

Strona 34 - E. Performance Data

4E. Performance Data ... 34. DCM-750BAH(-OS) ...

Strona 35

40Problem Possible Cause Remedy[3]Ice purge cycle will not start.a) Water Control Relay . Low water safety circuit open (bad contacts ).. Replace.b

Strona 36 - A. Diagnostic Procedure

4Problem Possible Cause Remedy[5] All components run, but no ice is produced. (continued)d) Evaporator . Defective. . Replace.e) Water Supply Line

Strona 37 - B. Ice Production Check

43. OtherProblem Possible Cause Remedy[]Icemaker will not stop when bin is lled with ice.a)Bin Control . Actuator sticking. . Adjust or replace.

Strona 38 - C. Diagnostic Charts

43Problem Possible Cause Remedy[4] Gear motor overload protector operates frequently or fuse blows frequently.a)Power Supply . Not within specicatio

Strona 39

44Problem Possible Cause Remedy[]Abnormal noise. a) Gear Motor or Gear Head. Bearing worn out. . Replace.b) Auger Mechanism . Bad alignment of aug

Strona 40

45Problem Possible Cause Remedy[]No water dispensed. a) OS Sensor . Dirty sensor. . Clean..Defective. . See chart 5c below.b) Dispense Mode Switc

Strona 41 - 2. Low Ice Production

46V. Removal and Replacement of ComponentsIMPORTANT. Ensure all components, fasteners, and thumbscrews are securely in place after the equipment is s

Strona 42 - 3. Other

47) Always install a new drier every time the sealed refrigeration system is opened. Do not replace the drier until after all other repair or replace

Strona 43 - 4. Dispensing

48B. Removal and Replacement of CompressorIMPORTANTAlways install a new drier every time the sealed refrigeration system is opened. Do not replace the

Strona 44 - 5. Opti Serve (OS) Sensors

49C. Removal and Replacement of Expansion ValveIMPORTANTSometimes moisture in the refrigeration circuit exceeds the drier capacity andfreezes up at th

Strona 45 - 5c. Water Dispensing

5I. SpecicationsA. Icemaker1. DCM-750BAHNote: We reserve the right to make changes in specications and design without prior notice.AC SUPPLY VOLTAGE

Strona 46

50Fig. 1Extruding Head and Upper BearingEvaporatorAllen Head Cap Screw with Washer Allen Head Cap ScrewHousing and Lower BearingGear MotorBarrier/Capa

Strona 47

51. Upper Bearing Wear Check To ensure that the bearing inside the extruding head does not exceed the wear tolerance of .0", follow the instruc

Strona 48

58) Replace spout A, spout B, and the front cover of the storage bin in their correct positions.9) Move the power switch to the "ON" positi

Strona 49

533) Remove the apron panel, then remove the left side panel.4) Recover the refrigerant and store it in an approved container.5) Disconnect the drip t

Strona 50

545. Removal and Replacement of Mechanical Seal and Lower Housing 5a. Mechanical Seal) Move the control switch to the "DRAIN" position and

Strona 51

558) Move the power switch to the "ON" position, then replace the panels in their correct positions.9) Turn on the power supply, then mov

Strona 52

56E. Removal and Replacement of Self-Contained Air-Cooled CondenserIMPORTANTAlways install a new drier every time the sealed refrigeration system is o

Strona 53

57F. Removal and Replacement of Water-Cooled CondenserIMPORTANTAlways install a new drier every time the sealed refrigeration system is opened. Do not

Strona 54

58G. Removal and Replacement of Water Regulating Valve - Water-Cooled Model OnlyIMPORTANTAlways install a new drier every time the sealed refrigeratio

Strona 55

590) Move the power switch to the "ON" position, then replace the panels in their correct positions.) Turn on the power supply, then move

Strona 56

62. DCM-750BAH-OSNote: We reserve the right to make changes in specications and design without prior notice.AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120

Strona 57

60J. Removal and Replacement of Inlet or Dispensing Water Valve) Close the water supply line shut-off valve.) Open the water supply line drain valve

Strona 58 - Water-Cooled Model Only

60) Open the water supply line shut-off valve.) Turn on the power supply, move the power switch to the "ON" position, then replace the f

Strona 59

66) Install the new motor.7) Assemble the removed parts in the reverse order of which they were removed.8) Move the power switch to the "ON"

Strona 60

63VI. Cleaning and MaintenanceIMPORTANTEnsure all components, fasteners, and thumbscrews are securely in place after any cleaning or maintenance is do

Strona 61

641. Water Systema) Cleaning SolutionDilute 9.6 . oz. (0.9 l) of recommended cleaner, Hoshizaki "Scale Away" or "LIME-A-WAY" (Ec

Strona 62

653) Move the control switch to the "OFF" position, then turn off the power supply.4) Close the water supply line shut-off valve.c) Saniti

Strona 63 - VI. Cleaning and Maintenance

663) Remove the front cover of the storage bin.4) Remove the motor bracket thumbscrews, rst from the vertical plane and then from the horizontal plan

Strona 64

67B. MaintenanceThis icemaker must be maintained individually, referring to the instruction manual and labels provided with the icemaker. The schedule

Strona 65

68C. Preparing the Icemaker for Long StorageCAUTIONWhen the icemaker is not used for two or three days under normal conditions, it is sufcient to onl

Strona 66

692. On water-cooled model only, remove the water from the water-cooled condenser:) Make sure the control switch and the power switch are in the &quo

Strona 67 - B. Maintenance

7Note: We reserve the right to make changes in specications and design without prior notice.3. DCM-750BWHAC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V

Strona 68

84. DCM-750BWH-OSNote: We reserve the right to make changes in specications and design without prior notice.AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120

Strona 69

9II. General InformationA. Construction1. DCM-750BAH(-OS)Storage BinInlet Water ValveReservoirControl BoxAir-Cooled CondenserSpout CoverEvaporator Ass