Hoshizaki L1F015102 Instrukcja Użytkownika Strona 10

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 22
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 9
7
C. Location
WARNING
This icemaker is not intended for outdoor use. Normal operating ambient
temperature should be within +45°F to +100°F (+7°C to +38°C); Normal
operating water temperature should be within +45°F to +90°F (+7°C to +32°
C). Operation of the icemaker, for extended periods, outside of these normal
temperature ranges may affect production capacity.
For best operating results:
* The icemaker should not be located next to ovens, grills or other high heat producing
equipment.
* Level the icemaker from side to side and front to rear by adjusting the legs. The location
should provide a firm and level foundation for the equipment.
* Avoid a site where dripping is not allowed.
* This icemaker will not work at subfreezing temperatures. To prevent damage to the water
supply line, drain the icemaker when air temperature is below zero.
* Allow at least 2” (5 cm) clearance at the right side for proper air circulation and at least 0.6”
(15 mm) clearance at top for ease of maintenance and/or service.
Fig. 1
Air Inlet*
(Air Filter)
Louver
Magnet Catch
Air Filter*
Door
Separator
(inside)
How to remove Louver
* KM-201BAH, KM-260BAH only
Przeglądanie stron 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 21 22

Komentarze do niniejszej Instrukcji

Brak uwag